Cummins 75kW Diesel Generator Set
Wheeled design: Durable four wheels enable flexible mobility, suitable for indoor/outdoor use, available as an option.
Technical Parameters of Cummins 75kW Diesel Generator
1. Reliable automatic voltage regulator excitation system, providing constant excitation under various conditions.
2. Easily enables parallel operation with the power grid or other generators.
3. Dynamically balanced rotor with sealed ball bearings, available in both single-bearing and double-bearing configurations.
4. Easy to install and convenient for maintenance, featuring easy-to-operate terminals, rotating diodes and coupling bolts.
5. Multi-standard transition sleeves and single-bearing disc-type couplings.
6. Compliant with all major land-based standards.

| Configuration selection |
| Product advantages |
| Product Description |
| GENERATOR SET TECHNICAL PARAMETERS | |||
| Model: | HLC75GF | Voltage Regulation: | ≥±5% |
| Prime Power (KVA/KW): | 93.75/75 | Voltage Regulation, Stead State: | ≤±1% |
| Standby Power (KVA/KW): | 103/82.5 | Sudden Voltage Warp: | ≤+25% |
| Rated Current (A): | 135 | Sudden Voltage Warp: | ≤-20% |
| Power Factor (COSΦ): | 0.8 lagging | Voltage Stable Time: | ≤6S |
| Rated Frequency: | 50Hz | Voltage unbalance: | ≤1% |
| Starting Method: | 24V DC start | Frequency Regulation, Stead State: | ≤5% |
| Dimensions (mm): | 1900*900*1400 | Frequency Waving: | ≤1.5% |
| Weight (kg): | 950 | Frequency Recovery Time: | ≤5S |
| DIESEL ENGINE DATA | |||
| Brand: | Cummins | Compression Ratio: | 18:01 |
| Model: | 4BTA3.9-G13 | Fuel Consumption Rate (g/kwh): | 210 |
| Rate Power (kw): | 87 | Rated Speed: | 1500/RPM |
| Standby Power (kw): | 97 | Air Intake System: | Turbocharged |
| Number of Cylinders: | 4 | Type: | Four-stroke、Direct injection |
| Displacement (L): | 3.9 | Cooling Mode: | Closed water cooling |
| Bore/Stroke (mm): | 102/120 | Start Mode: | Electric starting |
| ALTERNATOR DATA | |||
| Brand: | HAOLIAN | Power Factor (COSΦ): | 0.8 lagging |
| Model: | HL-75 | Insulation Class: | H |
| Rated Power (KVA): | 93.75 | Protection Class: | IP22 IP23 |
| Rated Voltage (V): | 400/230 | Voltage Regulation Method: | AVR (Automatic Regulation) |
| Number of bearing: | 1 | Wiring Method: | 3 phase and 4 wires,"Y" type connecting |




A: Supports both electric and manual starting options, with easy operation to meet needs.
A: Wheeled design with durable four wheels enables flexible indoor/outdoor movement.
A: Enables convenient parallel operation with the grid or other generators for multi-unit collaboration.
EN
AR
CS
NL
FR
DE
IT
JA
KO
PL
PT
RU
ES
UK
TH
TR









