The Cummins 100kW diesel generator set, boasting ultra-high efficiency of 35%-45%, a design life of 30,000 hours, and voltage accuracy of ±1%, has become the preferred choice for stable power supply in industrial fields. Its intelligent control system and precision selection further enhance its significant advantages in long-term operating costs.

| GENERATOR SET TECHNICAL PARAMETERS |
| Model: | HLC100GF | Voltage Regulation: | ≥±5% |
| Prime Power (KVA/KW): | 125/100 | Voltage Regulation, Stead State: | ≤±1% |
| Standby Power (KVA/KW): | 137.5/110 | Sudden Voltage Warp: | ≤+25% |
| Rated Current (A): | 180 | Sudden Voltage Warp: | ≤-20% |
| Power Factor (COSΦ): | 0.8 lagging | Voltage Stable Time: | ≤6S |
| Rated Frequency: | 50Hz | Voltage unbalance: | ≤1% |
| Starting Method: | 24V DC start | Frequency Regulation, Stead State: | ≤5% |
| Dimensions (mm): | 2500*900*1600 | Frequency Waving: | ≤1.5% |
| Weight (kg): | 1300 | Frequency Recovery Time: | ≤5S |
| DIESEL ENGINE DATA |
| Brand: | Cummins | Compression Ratio: | 17.3:1 |
| Model: | 6BTAA5.9-G2 | Fuel Consumption Rate (g/kwh): | 216 |
| Rate Power (kw): | 120 | Rated Speed: | 1500/RPM |
| Standby Power (kw): | 130 | Air Intake System: | Turbocharger |
| Number of Cylinders: | 6 | Type: | Four-stroke、Direct injection |
| Displacement (L): | 5.9 | Cooling Mode: | Closed water cooling |
| Bore/Stroke (mm): | 102/120 | Start Mode: | Air-to-Air Intercooled |
| ALTERNATOR DATA |
| Brand: | HAOLIAN | Power Factor (COSΦ): | 0.8 lagging |
| Model: | HL-100 | Insulation Class: | H |
| Rated Power (KVA): | 125 | Protection Class: | IP22 IP23 |
| Rated Voltage (V): | 400/230 | Voltage Regulation Method: | AVR (Automatic Regulation) |
| Number of bearing: | 1 | Wiring Method: | 3 phase and 4 wires,"Y" type connecting |
Please note:
1. Alternators can be selected according to the needs of customers are Haolian, Stanford, Leroy- Somer, Marathon and other famous brands.
2. The specifications may change without the notice.




FAQs Related to Cummins 100kW Diesel Generator Set:
Q: Does the voltage accuracy adapt to sensitive electrical equipment?
A: Yes, the ±1% voltage accuracy meets the power supply needs of sensitive equipment in hospitals, data centers, etc.
Q: Is performance degradation controllable after long-term operation?
A: Optimized design ensures minimal stable performance degradation during long-term operation, extending the effective service cycle.
Q: How does intelligent control enhance usability?
A: The intelligent control system optimizes operating parameters and supports precise management to reduce operational complexity.