Cummins 500kW Diesel Generator Set
1. The cylinder block of the Cummins 500kW diesel generator set features a robust and durable design, exhibiting low vibration and reduced noise levels. 2. Incorporating a four-stroke configuration, it achieves stable operation with high efficiency. 3. Equipped with replaceable wet cylinder liners, it delivers an extended service life and enables convenient maintenance.
4. Boasting a two-cylinder-per-head layout and 4 valves per cylinder, it ensures adequate air intake. Complemented by forced water cooling, it minimizes heat radiation while delivering superior performance.

| Configuration selection |
| Product advantages |
| Product Description |
| GENERATOR SET TECHNICAL PARAMETERS | |||
| Model: | HLC500GF | Voltage Regulation: | ≥±5% |
| Prime Power (KVA/KW): | 625/500 | Voltage Regulation, Stead State: | ≤±1% |
| Standby Power (KVA/KW): | 687.5/550 | Sudden Voltage Warp: | ≤+25% |
| Rated Current (A): | 900 | Sudden Voltage Warp: | ≤-20% |
| Power Factor (COSΦ): | 0.8 lagging | Voltage Stable Time: | ≤6S |
| Rated Frequency: | 50Hz | Voltage unbalance: | ≤1% |
| Starting Method: | 24V DC start | Frequency Regulation, Stead State: | ≤5% |
| Dimensions (mm): | 3700×1550×1940 | Freq uency Waving: | ≤1.5% |
| Weight (kg): | 5600 | Frequency Recovery Time: | ≤5S |
| DIESEL ENGINE DATA | |||
| Brand: | Cummins | Compression Ratio: | 14.5:1 |
| Model: | KTAA19-G6A | Fuel Consumption Rate (g/kwh): | 206 |
| Rate Power (kw): | 570 | Rated Speed: | 1500/RPM |
| Standby Power (kw): | 610 | Air Intake System: | Turbocharger |
| Number of Cylinders: | 6 | Type: | Four-stroke、Direct injection |
| Displacement (L): | 18.9 | Cooling Mode: | Closed water cooling |
| Bore/Stroke (mm): | 159/159 | Start Mode: | Electric starting |
| ALTERNATOR DATA | |||
| Brand: | HAOLIAN | Power Factor (COSΦ): | 0.8 Lagging |
| Model: | HL-500 | Insulation Class: | H |
| Rated Power (KVA): | 625 | Protection Class: | IP22 IP23 |
| Rated Voltage (V): | 400/230 | Voltage Regulation Method: | AVR (Automatic Regulation) |
| Number of bearing: | 1 | Wiring Method: | 3 phase and 4 wires,"Y" type connecting |




Q: How convenient is the maintenance of this generator set?
A: It features a two-cylinder-per-head structure with rational component layout; key vulnerable parts are easy to replace, making daily maintenance simple.
Q: Can its performance meet the needs of diverse power consumption scenarios?
A: Relying on the four-stroke design and 4-valve-per-cylinder configuration, it ensures sufficient air intake; combined with a forced water cooling system, it has low heat radiation and can efficiently and stably adapt to industrial, commercial and other scenarios.