Perkins 360kW Diesel Generator Set
The Perkins 360kW diesel generator set features a four-stroke inline six-cylinder design, which is compact in structure and operates stably, delivering strong power output. Turbocharging and intercooling technology increase intake pressure and density, enhancing engine power and torque while reducing fuel consumption and emissions.

| Configuration selection |
| Product advantages |
| Product Description |

| GENERATOR SET TECHNICAL PARAMETERS | |||
| Model: | HLP360GF | Steady-State Voltage Regulation: | ≤ ±0.5% |
| Prime Power (KVA/KW): | 450/360 | Transient Voltage Regulation: | ≤ ±15% |
| Standby Power (KVA/KW): | 495/396 | Voltage Fluctuation Rate: | ≤ ±0.5% |
| Rated Current (A): | 648 | Voltage Waveform Distortion: | ≤ 5% |
| Power Factor (COSΦ): | 0.8 lagging | Voltage Recovery Time: | ≤ 1.5 sec |
| Rated Frequency: | 50Hz | Steady-State Frequency Regulation: | ≤ ±2% |
| Starting Method: | 24V DC start | Transient Frequency Regulation: | ≤ ±5% |
| Dimensions (mm): | 4000×1200×2100 | Frequency Recovery Time: | ≤ 3 sec |
| Weight (kg): | 3700 | Frequency Fluctuation Rate: | ≤ ±0.5% |
| DIESEL ENGINE DATA | |||
| Brand: | Perkins | Compression Ratio: | 16:1 |
| Model: | 2506C-E15TAG1L | Fuel Consumption Rate (g/kwh): | 211 |
| Rate Power (kw): | 396 | Rated Speed: | 1500/RPM |
| Standby Power (kw): | 435 | Air Intake System: | Turbocharger |
| Number of Cylinders: | 6 | Type: | Four-stroke、Direct injection |
| Displacement (L): | 15.2 | Cooling Mode: | Closed water cooling |
| Bore/Stroke (mm): | 137/171 | Start Mode: | Electric starting |
| ALTERNATOR DATA | |||
| Brand: | HAOLIAN | Power Factor (COSΦ): | 0.8 Lagging |
| Model: | HL-360 | Insulation Class: | H |
| Rated Power (KVA): | 400 | Protection Class: | IP22 IP23 |
| Rated Voltage (V): | 400/230 | Voltage Regulation Method: | AVR (Automatic Regulation) |
| Number of bearing: | 1 | Wiring Method: | 3 phase and 4 wires,"Y" type connecting |




FAQs Related to Perkins 360kW Diesel Generator Set:
Q: What advantages does the structural design of the Perkins 360kW diesel generator set offer?
A: It adopts a four-stroke inline six-cylinder design, featuring a compact structure and stable operation, adapting to space-constrained scenarios while ensuring power stability.
A: They enhance power and torque by improving intake efficiency, while optimizing combustion to reduce emissions, meeting high-efficiency and environmental protection needs.
Q: What practical significance does stable operation have for long-term use?
A: It reduces operational vibration and wear, extends equipment service life, and ensures continuous power supply in scenarios requiring uninterrupted operation.