Ricardo 20kW Diesel Generator Set
Rated Power: 20KVA
Standby Power: 22KVA
Rated Frequency: 50HZ
Rated Voltage: 220/380V
The normal startup of the Ricardo 20kW diesel generator set is affected by four key factors: Battery type and charge level: The type and charge level of the battery directly affect the startup success rate. Ambient temperature: Ambient temperature impacts the battery's discharge rate and the starting resistance torque of the diesel engine. Starting resistance torque: It includes internal friction resistance torque, initial compression resistance torque, and the inertial torque required to accelerate the engine from a static state to the starting speed. Starter motor power: The rated power of the starter motor is used to overcome the starting resistance torque, with energy entirely derived from the battery.

| Configuration selection |
| Product advantages |
| Product Description |
| GENERATOR SET TECHNICAL PARAMETERS | |||
| Model: | HLR20GF | Voltage Regulation: | ≥±5% |
| Prime Power (KVA/KW): | 25/20 | Voltage Regulation, Stead State: | ≤±1% |
| Standby Power (KVA/KW): | 27.5/22 | Sudden Voltage Warp: | ≤+20% |
| Rated Current (A): | 36 | Sudden Voltage Warp: | ≤-15% |
| Power Factor (COSΦ): | 0.8 lagging | Voltage Stable Time: | ≤5S |
| Rated Frequency: | 50Hz | Voltage unbalance: | ≤1% |
| Starting Method: | 12V DC start | Frequency Regulation, Stead State: | ≤±5% |
| Dimensions (mm): | 1600*700*950 | Frequency Waving: | ≤0.5% |
| Weight (kg): | 550 | Frequency Recovery Time: | ≤3S |
| DIESEL ENGINE DATA | |||
| Brand: | Ricardo | Compression Ratio: | 16.5:1 |
| Model: | K4100D/ZH4100D | Fuel Consumption Rate (g/kwh): | 258.4 |
| Rate Power (kw): | 30.2 | Rated Speed: | 1500/RPM |
| Standby Power (kw): | 33 | Air Intake System: | Naturally |
| Number of Cylinders: | 4 | Type: | Four-stroke、Direct injection |
| Displacement (L): | 3.61 | Cooling Mode: | Closed water cooling |
| Bore/Stroke (mm): | 100/115 | Start Mode: | Electric starting |
| ALTERNATOR DATA | |||
| Brand: | HAOLIAN | Power Factor (COSΦ): | 0.8 lagging |
| Model: | HL-20 | Insulation Class: | H |
| Rated Power (KVA): | 25 | Protection Class: | IP22 IP23 |
| Rated Voltage (V): | 400/230 | Voltage Regulation Method: | AVR (Automatic Regulation) |
| Number of bearing: | 1 | Wiring Method: | 3 phase and 4 wires,"Y" type connecting |




FAQs Related to Ricardo 20kW Diesel Generator Set:
Q: What is the practical difference between the rated power and standby power of the Ricardo 20kW diesel generator set?
A: The rated power of 20KVA meets daily stable power supply needs, while the standby power of 22KVA can temporarily handle load peaks, adapting to fluctuating power consumption scenarios.
Q: How does ambient temperature affect the startup performance of this generator set?
A: Through optimized battery adaptability and fuel fluidity design, it reduces the impact of low temperatures on starting resistance torque, ensuring startup reliability in varying temperature environments.
Q: What is the core guarantee of its starting system?
A: The combination of battery type, charge management, and starter motor power matching forms the starting guarantee, ensuring stable energy output to overcome starting resistance.