Ricardo 150kw Diesel Generator Set
The power output of the Ricardo 150kW diesel generator set is well-suited to the backup power needs of medium-sized commercial complexes, data centers, and similar venues. In the medical field, when paired with an ATS automatic transfer switch, it enables power recovery within 15 seconds, meeting the power security requirements of critical areas such as operating rooms and ICUs.

| Configuration selection |
| Product advantages |
| Product Description |
| GENERATOR SET TECHNICAL PARAMETERS | |||
| Model: | HLR150GF | Voltage Regulation: | ≥±5% |
| Prime Power (KVA/KW): | 187.5/150 | Voltage Regulation, Stead State: | ≤±1% |
| Standby Power (KVA/KW): | 206.25/165 | Sudden Voltage Warp: | ≤+20% |
| Rated Current (A): | 270 | Sudden Voltage Warp: | ≤-15% |
| Power Factor (COSΦ): | 0.8 lagging | Voltage Stable Time: | ≤5S |
| Rated Frequency: | 50Hz | Voltage unbalance: | ≤1% |
| Starting Method: | 24V DC start | Frequency Regulation, Stead State: | ≤±5% |
| Dimensions (mm): | 2400*880*1350 | Frequency Waving: | ≤0.5% |
| Weight (kg): | 1500 | Frequency Recovery Time: | ≤3S |
| DIESEL ENGINE DATA | |||
| Brand: | Ricardo | Compression Ratio: | 16:1 |
| Model: | R6110ZLD | Fuel Consumption Rate (g/kwh): | 218 |
| Rate Power (kw): | 187.5 | Rated Speed: | 1500/RPM |
| Standby Power (kw): | 165 | Air Intake System: | Turbocharger |
| Number of Cylinders: | 6 | Type: | Four-stroke、Direct injection |
| Displacement (L): | 7.69 | Cooling Mode: | Closed water cooling |
| Bore/Stroke (mm): | 108/135 | Start Mode: | Electric starting |
| ALTERNATOR DATA | |||
| Brand: | HAOLIAN | Power Factor (COSΦ): | 0.8 lagging |
| Model: | HL-150 | Insulation Class: | H |
| Rated Power (KVA): | 150 | Protection Class: | IP22 IP23 |
| Rated Voltage (V): | 400/230 | Voltage Regulation Method: | AVR (Automatic Regulation) |
| Number of bearing: | 1 | Wiring Method: | 3 phase and 4 wires,"Y" type connecting |




A: Relying on the high-pressure common rail fuel system and intelligent electronic control technology, it provides core support for stable power output and efficient operation.
A: When paired with an ATS automatic transfer switch, it enables power recovery within 15 seconds, meeting the power needs of critical areas such as operating rooms and ICUs.
A: Equipped with a cloud monitoring module, it enables remote operation and maintenance management, enhancing the convenience of equipment monitoring and maintenance.
EN
AR
CS
NL
FR
DE
IT
JA
KO
PL
PT
RU
ES
UK
TH
TR