SDEC 12kw Diesel Generator Set
Its low-noise design further addresses the pain point of traditional generators disturbing residents, expanding its application scenarios.
The SDEC 12kW diesel generator set can meet the demand of most small and medium-sized electrical equipment operating simultaneously, and can easily power devices such as air conditioners, welding machines and small machine tools.
Compared with gasoline engines, diesel engines have a longer service life and lower fuel consumption rate, with obvious economic advantages under continuous operation conditions.
Modern mute technology, by optimizing intake and exhaust systems and adding sound insulation enclosures, controls operating noise below 65 decibels — a level equivalent to normal conversation — and will not cause resident disturbance even when used at night.

| Configuration selection |
| Product advantages |
| Product Description |


| GENERATOR SET TECHNICAL PARAMETERS | |||
| Model: | HLS12GF | Steady-State Voltage Regulation: | ≤ ±0.5% |
| Prime Power (KVA/KW): | 15/12 | Transient Voltage Regulation: | ≤ ±15% |
| Standby Power (KVA/KW): | 16.5/13.2 | Voltage Fluctuation Rate: | ≤ ±0.5% |
| Rated Current (A): | 21.6 | Voltage Waveform Distortion: | ≤ 8% |
| Power Factor (COSΦ): | 0.8 lagging | Voltage Recovery Time: | ≤ 1.5 sec |
| Rated Frequency: | 50Hz | Steady-State Frequency Regulation: | ≤ 3% |
| Starting Method: | 24V DC start | Transient Frequency Regulation: | ≤ ±5% |
| Dimensions (mm): | 1400*600*900 | Frequency Recovery Time: | ≤ 3 sec |
| Weight (kg): | 580 | Frequency Fluctuation Rate: | ≤ ±0.5% |
| DIESEL ENGINE DATA | |||
| Brand: | SDEC | Compression Ratio: | 18:1 |
| Model: | 4Z2.3-G11 | Fuel Consumption Rate (g/kwh): | 240 |
| Rate Power (kw): | 16 | Rated Speed: | 1500/RPM |
| Standby Power (kw): | 18 | Air Intake System: | Turbocharger |
| Number of Cylinders: | 4 | Type: | Four-stroke、Direct injection |
| Displacement (L): | 2.3 | Cooling Mode: | Closed water cooling |
| Bore/Stroke (mm): | 85/100 | Start Mode: | Electric starting |
| ALTERNATOR DATA | |||
| Brand: | HAOLIAN | Power Factor (COSΦ): | 0.8 Lagging |
| Model: | HL-12 | Insulation Class: | H |
| Rated Power (KVA): | 15 | Protection Class: | IP22 IP23 |
| Rated Voltage (V): | 400/230 | Voltage Regulation Method: | AVR (Automatic Regulation) |
| Number of bearing: | 1 | Wiring Method: | 3 phase and 4 wires,"Y" type connecting |




A: It supports short-term light overload, which can meet the temporary load increase demand of small and medium-sized equipment and ensure uninterrupted power supply.
A: The basic protection can handle light rain, but it is recommended to use a rain cover in continuous rainy days to prevent rainwater from entering and affecting components.
A: No complicated operation is required; just check the oil and battery status, and it can be started and used normally after simple debugging.
EN
AR
CS
NL
FR
DE
IT
JA
KO
PL
PT
RU
ES
UK
TH
TR