SDEC 150kw Diesel Generator Set
The SDEC 150 kW Diesel Generator Set with a soundproof enclosure, featuring ultra-low noise of 65 dB, an ultra-long service life of 30,000 hours and an ultra-fast response of 0.3 seconds, has become the first choice for power support in high-demand scenarios such as medical institutions and data centers. Its localized service network ensures 4-hour rapid response, and its total lifecycle cost is 35% lower than that of imported models.

| Configuration selection |
| Product advantages |
| Product Description |


| GENERATOR SET TECHNICAL PARAMETERS | |||
| Model: | HLS150GF | Steady-State Voltage Regulation: | ≤ ±0.5% |
| Prime Power (KVA/KW): | 187.5/150 | Transient Voltage Regulation: | ≤ ±15% |
| Standby Power (KVA/KW): | 206.25/165 | Voltage Fluctuation Rate: | ≤ ±0.5% |
| Rated Current (A): | 270 | Voltage Waveform Distortion: | ≤ 8% |
| Power Factor (COSΦ): | 0.8 lagging | Voltage Recovery Time: | ≤ 1.5 sec |
| Rated Frequency: | 50Hz | Steady-State Frequency Regulation: | ≤ 3% |
| Starting Method: | 24V DC start | Transient Frequency Regulation: | ≤ ±5% |
| Dimensions (mm): | 2446*940*1376 | Frequency Recovery Time: | ≤ 3 sec |
| Weight (kg): | 1330 | Frequency Fluctuation Rate: | ≤ ±0.5% |
| DIESEL ENGINE DATA | |||
| Brand: | SDEC | Compression Ratio: | 17.3:1 |
| Model: | 6HTAA6.5-G33 | Fuel Consumption Rate (g/kwh): | 192 |
| Rate Power (kw): | 168 | Rated Speed: | 1500/RPM |
| Standby Power (kw): | 185 | Air Intake System: | Turbocharger |
| Number of Cylinders: | 6 | Type: | Four-stroke、Direct injection |
| Displacement (L): | 6.5 | Cooling Mode: | Closed water cooling |
| Bore/Stroke (mm): | 105/124 | Start Mode: | Electric starting |
| ALTERNATOR DATA | |||
| Brand: | HAOLIAN | Power Factor (COSΦ): | 0.8 Lagging |
| Model: | HL-150 | Insulation Class: | H |
| Rated Power (KVA): | 187.5 | Protection Class: | IP22 IP23 |
| Rated Voltage (V): | 400/230 | Voltage Regulation Method: | AVR (Automatic Regulation) |
| Number of bearing: | 1 | Wiring Method: | 3 phase and 4 wires,"Y" type connecting |




FAQs Related to SDEC 150kW Diesel Generator Set:
Q: What pre-treatment measures can users take if the Shangchai 150kW diesel generator set has difficulty starting in low-temperature environments (e.g., below -5℃)?
A: Users can turn on the unit's built-in low-temperature preheating device (e.g., cylinder block heater) for 15-20 minutes; switch to -10# or -20# low-pour-point diesel to prevent fuel waxing; inspect and insulate the starter battery to ensure stable battery output voltage, improving start success rate.
Q: What are the specific requirements for the type and replacement of engine oil and coolant for the unit during daily use?
A: Engine oil should be API CF-4 grade or higher with 15W-40 viscosity; replace it after the first 50 hours of use, and then every 250 hours thereafter; coolant should be long-acting antifreeze (freezing point ≤-35℃), mixed with pure water at a 1:1 ratio, replaced every 2 years or 3000 hours, and mixing different types of coolant is prohibited.
Q: What problems may occur if the unit is shut down directly after operation? What is the correct shutdown process?
A: Direct shutdown may damage the turbocharger due to insufficient heat dissipation or affect the next start due to residual engine oil. Correct process: First reduce the load to 0, keep the unit running at idle speed for 5-8 minutes, turn off the control switch after water temperature and oil temperature drop below 60℃, finally close the fuel cut-off valve, and clean dust on the unit surface after shutdown.